- Solutions
-
Products
- Level 4 EV Charging Station
- Level 3 EV Charging Station
- J1772 Charging Station
- NACS Charging Station
- CCS1 Charging Station
- CCS2 Charging Station
- Mode 4 EV Charger
- Mode 3 EV Charger
- Mode 2 EV Charger
- Level 2 EV Charging Station
- Level 1 EV Charging Station
- PV ESS EV Charging Station Wholesale
- Portable EV Charging Station
- AC Charging Station
- DC EV Charger
0102030405
China Factory Suppliers: 30|40kW EV DC Charging Station VoltPost Duo Olink® for Commercial Use
Olink
Parameter / Specification Sheet:
| Rated input voltage | 380Vac ± 20% (three-phase) |
| Rated output power | 40kW |
| Maximum input current | 150A (Three-phase) |
| Output constant power range | 1~150A |
| Voltage stabilization accuracy | ≤+0.5% |
| Output voltage | Within the range of 1–1000V |
| Charging method | Swipe card charging, scan code charging |
| Protection function | Overcurrent, Overvoltage, Undervoltage, Leakage Protection |
| Protection grade | IP54 |
| Charging interface | GB/T & CCS2 (dual gun) |
| Exposed gun line length | Standard configuration of 3 meters (customizable) |
| Work environment | Altitude: <2000m, Temperature: -20°C ~ 65°C, Derating work above 50°C |
| External dimensions | 644×238×680 (mm) |
| Number of charging guns | ONE |
| Human-computer interaction | 7-inch screen |
| Operation temperature | -25°C to 40°C |
| Humidity | 5% – 95% RH (no condensation) |
| Design standards | IEC-61851, ISO-15118 (European Standard), GB/T 18487.1 (National Standard) |
Olink
Product Appearance Structure Diagram (mm):
Olink
DC 40kW Column / Wall-mounted Charging Station Features & Appliance:
Energy Efficiency Revolution
96% peak conversion rate + 5,000 cycle lifespan, with a cost per kilowatt-hour (kWh) of less than $0.018.
Heavy-Duty Protection
MIL-STD-810G military certification, featuring a six-dimensional safety shield: overload, short circuit, water immersion, vibration, salt spray, and electromagnetic interference.
Smart Platform
5G + satellite dual-mode communication, pre-installed fleet management system, supporting networking and dispatching for up to 100 devices.
Extreme Output
1000V ultra-high voltage platform — commercial truck charging efficiency increased by 40% compared to traditional charging stations.
Features
- 96% energy efficiency + 15,000 cycle lifespan
- Five-dimensional safety protection (lightning / immersion / short circuit / overload / salt spray)
- Dual-mode smart management (4G / Ethernet), supports networking of thousands of devices
Suitable Charging Locations
The DC 40kW column / wall-mounted charging station is well-suited for a wide range of locations and scenarios, including:
- Urban public charging stations: Suitable for installation in urban areas and can cater to various vehicles.
- Urban public charging power stations: Can be deployed in public charging power stations that serve private cars, commuter cars, and buses.
- Parking lots and shopping malls: Ideal for installation in parking lots, including those found in shopping malls, offering EV owners convenient charging while they shop.
- Power business places: Can be deployed in power service centers or charging hubs, providing charging options for EV owners.
- Limited space deployment: Particularly suitable for locations with limited space — wall-mounted or floor-mounted for fast deployment in constrained areas.
Product Services & Customization:
🏭 Core of B2B Operational Infrastructure
Core of B2B Operational Infrastructure
- Protocol Ready for Deployment: Automaker-specific protocols integrated in 24 hours.
- Regional Lightning Kits: UL version for North America, CE version for the EU, explosion-proof version for the Middle East.
Download
DC 40kW Column / Wall-mounted Charging Station
Frequently Asked Questions (FAQ)
What is the output power of the Olink DC 40kW Wall-Mounted Charging Station?
The Olink DC Small charging station delivers a rated output power of 40kW, with an output voltage range of 1–1000V and a constant power output range of 1–150A, making it suitable for a wide variety of electric vehicles.
What charging interfaces does the Olink DC 40kW station support?
The station supports both GB/T and CCS2 (dual gun) charging interfaces, with a standard exposed gun line length of 3 meters (customizable), ensuring compatibility with a broad range of EV models worldwide.
What safety and protection features does this charging station include?
The Olink DC 40kW station features comprehensive five-dimensional safety protection, including overcurrent, overvoltage, undervoltage, leakage protection, and lightning/salt spray resistance. It achieves an IP54 protection grade and meets MIL-STD-810G military certification standards.
What communication and management capabilities does the station offer?
The station supports dual-mode smart management via 4G and Ethernet, enabling networking of thousands of devices. It comes pre-installed with a fleet management system and supports 5G + satellite dual-mode communication for remote monitoring and dispatching.
In what environments and locations can the Olink DC 40kW charger be installed?
This charging station is designed for flexible deployment. It can be wall-mounted or floor-mounted and is suitable for urban public charging stations, shopping mall parking lots, power business service centers, and locations with limited space. It operates in temperatures from -25°C to 65°C and altitudes below 2000m.
What international standards does the Olink DC 40kW charging station comply with?
The station complies with IEC-61851 and ISO-15118 (European Standard) as well as GB/T 18487.1 (Chinese National Standard). Regional customization is available, including UL certification for North America, CE certification for the EU, and explosion-proof versions for the Middle East.