The 30-40KW DC Charging Station (column/wall-mounted) is expertly engineered for high-intensity operations, making it an ideal choice for electric buses and logistics fleets. This advanced charging solution is designed to meet five worldwide standards: GB/T, CCS1, CCS2, CHAdeMO, and NACS, ensuring universal compatibility across various electric vehicle models, Experience ultra-fast charging capabilities that can deliver a full charge in just one hour. Built with industrial-grade cooling technology and IP55 protection, this charging station guarantees exceptional durability and efficiency, even in the most demanding environments, Available directly from a reputable manufacturer in China, this charging station benefits from a robust monthly production capacity of 50,000 units, ensuring you receive quick and reliable supply from trusted suppliers. Choose our 30-40KW DC Charging Station for a top-tier charging solution tailored for your electric vehicle needs
  • Brand Name Olink
  • Output Current DC
  • IP Rating IP55

Olink Parameter/Specification Sheet:
dc input ev charger Olink® DC 40kw Pillar Charging Station
Product Name DC 30~40KW pillar charging station
Rated input voltage 380Vac±20%(three-phase)
Rated power 30KW, 40KW
Maximum input current 100A (three-phase), 125A (three-phase)
Constant Output Current Range 0.5~100A
Voltage Regulation Accuracy ≤±0.5%
Output Voltage Range 200~1000V
Charging method Scan code for charging, swipe card for charging
Protection function Protection against overvoltage, undervoltage, overcurrent, short circuit, leakage, etc.
Protection level IP55
Charging interface GB/T 20234.2-2015
Exposed gun line length Standard configuration of 3 meters (customizable)
Work environment Altitude: <2000m, Temperature: -20℃~65℃, Derating work above 50°C
External dimensions 520mm*208mm*668mm (length*width*height)
Number of charging guns One
Human-computer interaction 7-inch screen
Working temperature -25°C to 40°C
Humidity 5%-95%RH (no condensation)
Communication protocol OCPP1.6
Support gun head GB/T
Design standards GB/T18487.1
Olink Product Appearance Structure Diagram (mm):
ev charger dc Olink® DC 40kw Pillar Charging Station
Olink DC 40kw Pillar Charging Station Features:

Security

Equipped with unique safety mechanisms such as pre-charging protection, main circuit safety detection, and remote diagnostic management.

Equipped with basic protection measures such as lightning protection, over/under security voltage, over-current, short circuit, and overtemperature.

Comprehensive charging protection functions and mechanisms effectively ensure the safety of personnel and vehicles, and guarantee safe and reliable charging operations.

Intelligence

Intelligent compatibility with both new and old national standard vehicles.

Reliability

Independently designed hardware and software for each layer, with high consistency, compatibility, and stability within the system.

The performance of voltage stabilization accuracy, current stabilization accuracy, ripple reliable coefficient, standby power consumption, etc. is better than the industry average level.

The system has high reliability and can be reliably charged in various environments.

Flexibility

Support APP, mini program, VIN code, card charging, and flexible authentication.

Energy Efficiency Revolution

96% peak conversion rate + 5,000 cycle lifespan, with a cost per kilowatt-hour (kWh) of less than $0.018.

Heavy-Duty Protection

MIL-STD-810G military certification, featuring a six-dimensional safety shield (overload, short circuit, water immersion, vibration, salt spray, electromagnetic interference).

Smart Platform

5G + satellite dual-mode communication, pre-installed fleet management system, supporting networking and dispatching for up to 100 devices.

Extreme Output

1000V ultra-high voltage platform, commercial truck charging efficiency increased by 40% compared to traditional charging stations.

Unlock Exclusive Pricing

Download

DC 40kw Pillar Charging Station

PDF

Product Services & Customization:
ev dc charging stations Olink® DC 40kw Pillar Charging Station

Core of B2B Operational Infrastructure

- Protocol Sovereignty: Automaker-specific protocols integrated in 48 hours

- Regional Readiness Kits: UL version for North America, CE version for Europe, sand-proof version for the Middle East

Frequently Asked Questions
Q What is the output voltage range of the Olink DC 40kW Pillar Charging Station?
The Olink DC 40kW Pillar Charging Station supports an output voltage range of 200V to 1000V, making it compatible with a wide variety of electric vehicles including commercial trucks and passenger cars requiring ultra-high voltage platforms.
Q What charging methods does the DC 40kW Pillar Charging Station support?
The station supports multiple authentication and charging methods including QR code scanning, RFID card swiping, APP charging, mini program access, and VIN code identification, offering flexible and convenient operation for various users.
Q What safety protections are built into the Olink DC 40kW charger?
The charger is equipped with comprehensive protection mechanisms including pre-charging protection, main circuit safety detection, lightning protection, overvoltage, undervoltage, overcurrent, short circuit, leakage protection, and overtemperature protection. It meets IP55 protection level standards for safe outdoor use.
Q Is the Olink DC 40kW Pillar Charging Station compatible with different regional standards?
Yes. Olink offers regional readiness kits tailored for different markets: UL-certified versions for North America, CE-certified versions for Europe, and sand-proof versions for Middle Eastern environments. Automaker-specific protocols can also be integrated within 48 hours.
Q What communication protocol does the DC 40kW charging station use?
The station uses OCPP 1.6 communication protocol and supports 5G + satellite dual-mode communication. The pre-installed fleet management system supports networking and dispatching for up to 100 devices simultaneously, making it ideal for large-scale fleet operations.
Q What are the operating temperature and environment requirements for the Olink DC 40kW charger?
The charger operates in a working temperature range of -25°C to 40°C (with derating above 50°C), humidity of 5%–95% RH (non-condensing), and at altitudes below 2000m. It is rated IP55 for protection against dust and water, ensuring reliable performance across diverse outdoor environments.

Olink Parameter/Specification Sheet:
dc input ev charger Olink® DC 40kw Pillar Charging Station
Product Name DC 30~40KW pillar charging station
Rated input voltage 380Vac±20%(three-phase)
Rated power 30KW, 40KW
Maximum input current 100A (three-phase), 125A (three-phase)
Constant Output Current Range 0.5~100A
Voltage Regulation Accuracy ≤±0.5%
Output Voltage Range 200~1000V
Charging method Scan code for charging, swipe card for charging
Protection function Protection against overvoltage, undervoltage, overcurrent, short circuit, leakage, etc.
Protection level IP55
Charging interface GB/T 20234.2-2015
Exposed gun line length Standard configuration of 3 meters (customizable)
Work environment Altitude: <2000m, Temperature: -20℃~65℃, Derating work above 50°C
External dimensions 520mm*208mm*668mm (length*width*height)
Number of charging guns One
Human-computer interaction 7-inch screen
Working temperature -25°C to 40°C
Humidity 5%-95%RH (no condensation)
Communication protocol OCPP1.6
Support gun head GB/T
Design standards GB/T18487.1
Olink Product Appearance Structure Diagram (mm):
ev charger dc Olink® DC 40kw Pillar Charging Station
Olink DC 40kw Pillar Charging Station Features:

Security

Equipped with unique safety mechanisms such as pre-charging protection, main circuit safety detection, and remote diagnostic management.

Equipped with basic protection measures such as lightning protection, over/under security voltage, over-current, short circuit, and overtemperature.

Comprehensive charging protection functions and mechanisms effectively ensure the safety of personnel and vehicles, and guarantee safe and reliable charging operations.

Intelligence

Intelligent compatibility with both new and old national standard vehicles.

Reliability

Independently designed hardware and software for each layer, with high consistency, compatibility, and stability within the system.

The performance of voltage stabilization accuracy, current stabilization accuracy, ripple reliable coefficient, standby power consumption, etc. is better than the industry average level.

The system has high reliability and can be reliably charged in various environments.

Flexibility

Support APP, mini program, VIN code, card charging, and flexible authentication.

Energy Efficiency Revolution

96% peak conversion rate + 5,000 cycle lifespan, with a cost per kilowatt-hour (kWh) of less than $0.018.

Heavy-Duty Protection

MIL-STD-810G military certification, featuring a six-dimensional safety shield (overload, short circuit, water immersion, vibration, salt spray, electromagnetic interference).

Smart Platform

5G + satellite dual-mode communication, pre-installed fleet management system, supporting networking and dispatching for up to 100 devices.

Extreme Output

1000V ultra-high voltage platform, commercial truck charging efficiency increased by 40% compared to traditional charging stations.

Unlock Exclusive Pricing

download

DC 40kw Pillar Charging Station

PDF

Product Services & Customization:
ev dc charging stations Olink® DC 40kw Pillar Charging Station

Core of B2B Operational Infrastructure

- Protocol Sovereignty: Automaker-specific protocols integrated in 48 hours

- Regional Readiness Kits: UL version for North America, CE version for Europe, sand-proof version for the Middle East

Frequently Asked Questions
What is the rated power output of the Olink DC 40kW Pillar Charging Station?
The Olink DC Pillar Charging Station supports rated power outputs of 30KW and 40KW, with an output voltage range of 200V to 1000V and a constant output current range of 0.5A to 100A.
What protection features does the Olink DC 40kW charger include?
The charger is equipped with comprehensive protection mechanisms including overvoltage, undervoltage, overcurrent, short circuit, leakage protection, lightning protection, overtemperature protection, pre-charging protection, and main circuit safety detection. It holds an IP55 protection rating.
What charging methods are supported by this DC pillar charging station?
The station supports multiple charging methods including QR code scanning, RFID card swiping, APP, mini program, VIN code, and flexible authentication, providing convenient options for various users.
What communication protocol does the Olink DC 40kW charger use?
The charger supports the OCPP 1.6 communication protocol, enabling seamless integration with charge point management systems (CPMS) and fleet management platforms. It also supports 5G + satellite dual-mode communication for up to 100 networked devices.
What are the operating environment requirements for this EV charger?
The charger operates at altitudes below 2000m, temperatures from -25°C to 40°C (with derating above 50°C), and humidity levels of 5%–95% RH (non-condensing). It is suitable for a wide range of outdoor and indoor environments.
Can the Olink DC 40kW Pillar Charging Station be customized for different regional standards?